Ihr Warenkorb

Ihr Warenkorb ist leer

Durchsuchen Sie Produkte und fügen Sie Artikel zu Ihrem Warenkorb hinzu

StartseiteProdukteLaboratoryLiquid HandlingDYNEX TECHNOLOGIES DSX Liquid Handling
DYNEX TECHNOLOGIES DSX Liquid Handling
Click to zoom
VERY GOOD

DYNEX TECHNOLOGIES DSX Liquid Handling

VERY GOODUnited StatesJahr 202696 AufrufeBasic
Auf Lager
€19,999.00

MwSt. & Versand werden an der Kasse berechnet

Antwortet in der Regel in 2 hours
Inspektionsbericht verfügbar
Weltweiter Versand verfügbar

Produktdetails

MarkeDYNEX TECHNOLOGIES
KategorieLiquid Handling
ZustandVERY GOOD
Jahr2026
Ship From🇺🇸
Veröffentlicht15 Sept 2026
Aufrufe96
Dynex Automated Liquid Handling Elisa System Units available (2) Condition: Excellent - just removed - recent PM by Dynex Warranty: 90 days ** (2) Units just removed from lab - recent PM by Dynex - Oct 2022 ** The DYNEX DSX® system provides extraordinary flexibility in your ELISA workflow. Our automated open system handles various assays and volumes simultaneously, with the speed and accuracy your laboratory requires. Advanced automation features at every stage of the workflow provide the walk away productivity your lab demands. Physical Specifications Dimensions Metric Non Metric Width: 106 cm Depth: 91 cm Height: 80 cm (42 in X 36 in X 32 in) Footprint: 0.98 sq m 10.5 sq ft Bench Weight: 136 kg (max.) 300 lbs (max.) Ship Weight: 244 kg (max.) 537 lbs (max.) Power Supply Requirements Voltage: 100 – 240 V automatic conversion Frequency: 50/60 Hz Power Consumption: < 800 VA (online UPS recommended) System Specifications Number of Plates: 4 Sample Capacity: 96 (98 positions available) Continuous Sample Loading: Yes Sample Tube Size: 10 mm – 16 mm diameter / 40 mm – 100 mm height Number of Reagents: Up to 24 (25 mL tubes) Number of Standard/Control Bottles: 33 (1.5 mL vials) Assays per Plate: 1 assay per strip or up to 12 assays per plate Dilution Wells Capacity: Up to 192 deep-well strips (24 x 8) Sample Tip Capacity: 432 (4 x 108) Reagent Tip Capacity: 41 tips Sample Pipetting Specifications Sample Tip Size: 300 µL Sample Pipetting Volume: 10 µL – 250 µL single-shot / 25 µL – 100 µL multi-shot Sample Pipetting Precision: ≤ 3% CV at any operating volume above 10 µL (single-shot mode) Estimated Cycle Time for Sample Pickup to Delivery on Plate: < 8 seconds Time to Dispense: 19 minutes (typical) 50 µL of 96 samples to plate from sample tubes or deep-well plates Sample Pipetting Accuracy: ± 2% of target volume at any operating Sampling Time w/ Dilutions: < 26 minutes (typical) Dilution Range: 1 part in 190 one-stage dilution 1 part in 36,100 two-stage dilution Process Security Liquid Level Sensing: Yes (reagents, controls and samples) Level Sensor System: Pressure differential Clot Detection: Yes Dispense Anomaly Detection: Yes Tip Detection: Yes Electronic Signature Pipetting: Yes Alarms: Yes Software Controlling Software: REVELATION DSX® Work Protocols (Assays): Unlimited Data Processing: Quantitative and qualitative Levey-Jennings: Yes Westgard Rules: Yes Process Reporting: Event log + error log Automatic Error Recovery: Yes Password Access Control: Yes Incubator Specifications Number of Incubators: Up to 4 Temperature Range: RT + 7° C to 50° C (elevated incubator) RT + 5° C (ambient incubator) Temperature Accuracy: ± 1° C Shaking: > 15 Hz periodic or continuous Temperature Monitoring: Yes Reagent Pipetting Specifications Reagent Tip Size: 1,300 μL Reagent Pipetting Volume: 25 μL – 1,000 μL Reagent Pipetting Precision: ≤ 3% CV at 10 shots at any volume in operating range above 50 μL Reagent Pipetting Accuracy: ± 2% of target volume at 50 μL or greater in operating range (single-shot mode) Reader Specifications Photometric Range: 0.000 – 3.000 OD Spectral Range: 405 nm – 690 nm Filter Slots: 6 wavelength Precision: ± 0.010 OD at 0.000 – 0.500 OD< 1% CV at 0.501 – 2.000 OD< 1.5% at 2.001 – 2.500 OD Accuracy: ± 0.01 OD or 2.5% (0.000 – 3.000 OD) whichever is greater Read Time: < 10 seconds, single wavelength< 20 seconds, dual wavelength Washer Specifications Manifold Configuration: 8-way Programmable Volumes: 50 μL – 999 μL Wash Buffer Capacity. 4 wash bottles at 2.0 L, with level-sensing Residual Wash Volume: < 3 μL per well with dual-axis sweep in a flat-bottom plate Dispense Precision: ≤ 5% CV (with 300 μL in a 96 well plate) Waste Container. 8 L with waste full sensor

Technische Spezifikationen

ConditionRefurbished
CountryUnited States
Warranty (month)3
AvailabilityIn stock
Type of analyzerclosed
Wavelength ranges, nm405-690
Sample size, microlitre10
Analizator typeAutomatic
Cycle time (reaction), s10
Weight (kg)244
ModelDSX
BrandDYNEX TECHNOLOGIES
CategoryLiquid Handling

Questions & Answers

Ask a Question

Questions are reviewed by our team before being published.

Gesperrt

Verkäuferinformationen ausgeblendet

Entsperren, um Name, Bewertung & Kontakt anzuzeigen

Verkäuferkontakt ist gesperrt

Entsperren Sie Telefon, E-Mail und vollständiges Profil des Verkäufers für eine einmalige Gebühr.

Sicherheitstipps

  • • Überprüfen Sie das Gerät vor der Zahlung
  • • Verwenden Sie die sichere MellMed-Zahlung
  • • Überprüfen Sie die Seriennummern
  • • Prüfen Sie CE/FDA-Konformitätsdokumente

Ihr Warenkorb

Ihr Warenkorb ist leer

Durchsuchen Sie Produkte und fügen Sie Artikel zu Ihrem Warenkorb hinzu